esequant ts2 studio software ver 1.17.0 (Qiagen)
Structured Review
Esequant Ts2 Studio Software Ver 1.17.0, supplied by Qiagen, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/esequant+ts2+studio+software/esequant+ts2/pm29615801-208-18-24
Average 90 stars, based on 1 article reviews
Images
Related Articles
Fluorescence:Article Title: Real-time Detection and Monitoring of Loop Mediated Amplification (LAMP) Reaction Using Self-quenching and De-quenching Fluorogenic Probes Article Snippet: The LAMP assay was run on the real-time fluorimeter, the ESEQuant TS2.6 (Qiagen GmbH, Lake Constance, Germany) instrument at 65 °C for 20 minutes, the optimal time and temperature as recommended by the manufacturer (Optigene). .. The instrument was programed to acquire the fluorescence signal every 30 sec. Amplification was flagged positive by the Amplification:Article Title: Real-time Detection and Monitoring of Loop Mediated Amplification (LAMP) Reaction Using Self-quenching and De-quenching Fluorogenic Probes Article Snippet: The LAMP assay was run on the real-time fluorimeter, the ESEQuant TS2.6 (Qiagen GmbH, Lake Constance, Germany) instrument at 65 °C for 20 minutes, the optimal time and temperature as recommended by the manufacturer (Optigene). .. The instrument was programed to acquire the fluorescence signal every 30 sec. Amplification was flagged positive by the Software:Article Title: Real-time Detection and Monitoring of Loop Mediated Amplification (LAMP) Reaction Using Self-quenching and De-quenching Fluorogenic Probes Article Snippet: The LAMP assay was run on the real-time fluorimeter, the ESEQuant TS2.6 (Qiagen GmbH, Lake Constance, Germany) instrument at 65 °C for 20 minutes, the optimal time and temperature as recommended by the manufacturer (Optigene). .. The instrument was programed to acquire the fluorescence signal every 30 sec. Amplification was flagged positive by the |
![Fluorescence signal from VZV62 dT-FAM probes. ( A ) Signal profile obtained after converting the Outer (VZV62F3), Inner (VZV62FIP) and Loop (VZV62LPB) primers into dT-FAM fluorescent probes. Input template concentration pVZV-ORF62 plasmid: 1 × 10 6 copies/µL. ( B ) Variation of fluorescence signal intensity due to varying levels of the Base Mix ranging from 0.5X, 1.0X, 1.5X, 2.0X and 2.5X. Input template concentration pVZV-ORF62 plasmid: 1 × 10 6 copies/µL. Water was used as a negative control. Each Time[30 sec interval] unit (X-axis) represents 30 seconds on the <t>ESEQuant</t> instrument.](https://pub-med-central-images-cdn.bioz.com/pub_med_central_ids_ending_with_3045/pmc05883045/pmc05883045__41598_2018_23930_Fig1_HTML.jpg)